Diameter of Wire Rope (inches)Minimum Length of SlingRated Capacity In Tons of 2,000 Lbs.Open SocketsClosed Sockets
Dim.
O
(Inches)
Dim.
D
(Inches)
Dim.
W
(Inches)
Dim.
L
(Inches)
Dim.
K
(Inches)
1/2”1’3”2.661”1”1.16”2.25”0.88”
5/8”1’6”4.121.25”1.19”1.41”2.5”1.00”
3/4”1’9”5.881.5”1.38”1.66”3”1.25”
7/8”2’7.961.75”1.63”1.88”3.5”1.50”
1”2’6”10.342”2”2.3”4”1.75”
1-1/8”2’9”13.002.25”2.25”2.56”4.5”2.00”
1-1/4”3’15.982.5”2.5”2.81”5”2.25”
1-3/8”3’19.202.5”2.5”2.81”5”2.25”
1-1/2”3’3”22.803”2.75”3.19”6”2.75”
1-3/4”4’3”30.603.5”3.5”3.75”7.56”3.13”
2”4’9”39.604”3.75”4.38”8.56”3.75”
2-1/4”5’49.404.5”4.25”5”9.5”4.00”
2-1/2”5’9”60.405”4.75”5.5”10.62”4.50”
2-3/4”6’3”72.205.25”5”6.25”11.25”4.88”
3”6’9”85.005.75”5.25”6.75”11.75”5.25”
3-1/4”7’3”98.406.25”5.5”7.25”12.25”5.75”
3-1/2”7’6”112.806.75”6”7.75”13”6.25”
3-3/4”8’3”126.407.5”7”8.5”14”7.00”
4”8’6”142.607.5”7”8.5”14”7.00”

Socket assemblies are to extract length +/- 1/4″.
All assemblies are proof-tested to 40% of catalog breaking strength.
All capacities are based on extra-improved plow steel (EIPS).
Enhanced capacity based on extra-improve plow steel (EIPS). EEIPS is also available upon request.

All slings are proof-tested to 2 times working load limit. Design factor is 5:1.

Diameter of Wire Rope (inches)Minimum Length of SlingRated Capacity In Tons of 2,000 Lbs.Open SocketsClosed Sockets
Dim.
O
(Inches)
Dim.
D
(Inches)
Dim.
E
(Inches)
Dim.
K
(Inches)
Dim.
W
(Inches)
1/4”0’11”0.690.69”0.69”1.15”0.5”0.75”
5/16”1’3”1.050.81”0.81”1.36”0.67”0.88”
3/8”1’3”1.500.81”0.81”1.36”0.67”0.88”
7/16”1’8”2.041”1”1.5”0.86”1.06”
1/2”1’8”2.661”1”1.5”0.86”1.06”
9/16”2’0”3.361.25”1.19”1.65”1.13”1.25”
5/8”2’0”4.121.25”1.19”1.65”1.13”1.25”
3/4”2’5”5.881.5”1.38”2.06”1.31”1.44”
7/8”2’10”7.961.75”1.62”2.44”1.5”1.69”
1”3’2”10.342”2”2.75”1.75”2.06”
1-1/8”3’7”13.002.25”2.25”3.13”2”2.31”
1-1/4”4’0”15.982.5”2.5”3.5”2.25”2.56”
1-3/8”4’5”19.202”2.5”4”2.25”2.56”
1-1/2”4’9”22.803”2.75”4.38”2.5”2.81”
1-3/4”5’5”30.603.5”3.5”5”3”3.56”
2”6’4”39.604”3.75”6.13”3.25”3.81”

Socket assemblies can be ordered pre-stretched and measured under load to exact length +/- 1/4″.
All assemblies are proof-tested to 40% of catalog breaking strength.
All capacities are based on extra-improved plow steel (EIPS). EEIPS is also available upon request.
Enhanced capacity based on extra-improve plow steel (EIPS). EEIPS is also available upon request.

All slings are proof-tested to 2 times working load limit. Design factor is 5:1.

Diameter of Wire Rope (inches)
Minimum Length of Sling
Rated Capacity In Tons of 2,000 Lbs.
Open Sockets
Dim.O (Inches)
Open Sockets
Dim. D (Inches)
Open Sockets
Dim. W (Inches)
Closed Sockets
Dim. L (Inches)
Closed Sockets
Dim. K (Inches)
1/2”
1’3”
2.66
1”
1”
1.16”
2.25”
0.88”
5/8”
1’6”
4.12
1.25”
1.19”
1.41”
2.5”
1.00”
3/4”
1’9”
5.88
1.5”
1.38”
1.66”
3”
1.25”
7/8”
2’
7.96
1.75”
1.63”
1.88”
3.5”
1.50”
1”
2’6”
10.34
2”
2”
2.3”
4”
1.75”
1-1/8”
2’9”
13.00
2.25”
2.25”
2.56”
4.5”
2.00”
1-1/4”
3’
15.98
2.5”
2.5”
2.81”
5”
2.25”
1-3/8”
3’
19.20
2.5”
2.5”
2.81”
5”
2.25”
1-1/2”
3’3”
22.80
3”
2.75”
3.19”
6”
2.75”
1-3/4”
4’3”
30.60
3.5”
3.5”
3.75”
7.56”
3.13”
2”
4’9”
39.60
4”
3.75”
4.38”
8.56”
3.75”
2-1/4”
5’
49.40
4.5”
4.25”
5”
9.5”
4.00”
2-1/2”
5’9”
60.40
5”
4.75”
5.5”
10.62”
4.50”
2-3/4”
6’3”
72.20
5.25”
5”
6.25”
11.25”
4.88”
3”
6’9”
85.00
5.75”
5.25”
6.75”
11.75”
5.25”
3-1/4”
7’3”
98.40
6.25”
5.5”
7.25”
12.25”
5.75”
3-1/2”
7’6”
112.80
6.75”
6”
7.75”
13”
6.25”
3-3/4”
8’3”
126.40
7.5”
7”
8.5”
14”
7.00”
4”
8’6”
142.60
7.5”
7”
8.5”
14”
7.00”

Socket assemblies are to extract length +/- 1/4″.
All assemblies are proof-tested to 40% of catalog breaking strength.
All capacities are based on extra-improved plow steel (EIPS).
Enhanced capacity based on extra-improve plow steel (EIPS). EEIPS is also available upon request.

All slings are proof-tested to 2 times working load limit. Design factor is 5:1.

Diameter of Wire Rope (inches)
Minimum Length of Sling
Rated Capacity In Tons of 2,000 Lbs.
Open Sockets
Dim.O (Inches)
Open Sockets
Dim. D (Inches)
Open Sockets
Dim. E (Inches)
Closed Sockets
Dim. K (Inches)
Closed Sockets
Dim. W (Inches)
1/4”
0’11”
0.69
0.69”
0.69”
1.15”
0.5”
0.75”
5/16”
1’3”
1.05
0.81”
0.81”
1.36”
0.67”
0.88”
3/8”
1’3”
1.50
0.81”
0.81”
1.36”
0.67”
0.88”
7/16”
1’8”
2.04
1”
1”
1.5”
0.86”
1.06”
1/2”
1’8”
2.66
1”
1”
1.5”
0.86”
1.06”
9/16”
2’0”
3.36
1.25”
1.19”
1.65”
1.13”
1.25”
5/8”
2’0”
4.12
1.25”
1.19”
1.65”
1.13”
1.25”
3/4”
2’5”
5.88
1.5”
1.38”
2.06”
1.31”
1.44”
7/8”
2’10”
7.96
1.75”
1.62”
2.44”
1.5”
1.69”
1”
3’2”
10.34
2”
2”
2.75”
1.75”
2.06”
1-1/8”
3’7”
13.00
2.25”
2.25”
3.13”
2”
2.31”
1-1/4”
4’0”
15.98
2.5”
2.5”
3.5”
2.25”
2.56”
1-3/8”
4’5”
19.20
2”
2.5”
4”
2.25”
2.56”
1-1/2”
4’9”
22.80
3”
2.75”
4.38”
2.5”
2.81”
1-3/4”
5’5”
30.60
3.5”
3.5”
5”
3”
3.56”
2”
6’4”
39.60
4”
3.75”
6.13”
3.25”
3.81”

Socket assemblies can be ordered pre-stretched and measured under load to exact length +/- 1/4″.
All assemblies are proof-tested to 40% of catalog breaking strength.
All capacities are based on extra-improved plow steel (EIPS). EEIPS is also available upon request.
Enhanced capacity based on extra-improve plow steel (EIPS). EEIPS is also available upon request.

All slings are proof-tested to 2 times working load limit. Design factor is 5:1.