2 Leg Bridle Slings – Holloway Houston, Inc.
Wire Rope Diameter (inches)EIPS Capacities In Tons
Angle With Horizontal
Recommended Master LinkRecomm.Shackle
Size
Recomm. Eye HooksMinimum Sling Length
60 Deg45 Deg30 DegDia.Width.Length(Inches)
1/4”1.10.910.651/2”2.5”5”3/8”3/4 ton1’3”
3/8”2.52.01.45/8”3”6”1/2”1.5 ton1’8”
1/2”4.43.62.53/4”2.75”5.5”5/8”3 ton2’0”
5/8”6.85.53.91”3.5”7”3/4”5 ton2’4”
3/4”9.77.95.61”3.5”7”7/8”7 ton2’9”
7/8”13117.61-1/4”4.3”8.75”1”7.5 ton3’3”
1”17149.81-1/2”5.25”11.5”1-1/8”10 ton3’6”
1-1/8”2117121-1/2”5.25”11.5”1-1/4”15 ton4’0”
1-1/4”2621151-3/4”6”12”1-3/8”15 ton4’6”
1-3/8”3125182”7”14”1-1/2”20 ton5’0”
1-1/2”3730212”7”14”1-3/4”22 ton5’6”
1-3/4”4940282-1/4”8”16”2”30 ton6’6”
2”6352372-1/2”8”16”2-1/2”37 ton8’0”
2 -1/4”7763442-3/4”9”16”2-1/2”8’9”

WHEN USING IN BASKET OR CHOKER CONFIGURATION, TAKE LIFTING ANGLES INTO CONSIDERATION. TO OBTAIN FULL RATED CAPACITY, THE PIN THAT THE EYE OF THE SLING PASSES OVER MUST BE A MINIMUM OF 4 TIMES THE DIAMETER OF THE COMPONENT WIRE ROPE.

All slings are proof-tested to 2 times working load limit. Design factor is 5:1

Wire Rope Diameter (inches)
EIPS Capacities In Tons
Angle With Horizontal 60 Deg
EIPS Capacities In Tons
Angle With Horizontal 45 Deg
EIPS Capacities In Tons
Angle With Horizontal 30 Deg
Recommended Master Link Dia.
Recommended Master Link Width.
Recommended Master Link Length
 Recomm.Shackle
Size (Inches)
Recomm. Eye Hooks
Minimum Sling Length
1/4”
1.1
0.91
0.65
1/2”
2.5”
5”
3/8”
3/4 ton
1’3”
3/8”
2.5
2.0
1.4
5/8”
3”
6”
1/2”
1.5 ton
1’8”
1/2”
4.4
3.6
2.5
3/4”
2.75”
5.5”
5/8”
3 ton
2’0”
5/8”
6.8
5.5
3.9
1”
3.5”
7”
3/4”
5 ton
2’4”
3/4”
9.7
7.9
5.6
1”
3.5”
7”
7/8”
7 ton
2’9”
7/8”
13
11
7.6
1-1/4”
4.3”
8.75”
1”
7.5 ton
3’3”
1”
17
14
9.8
1-1/2”
5.25”
11.5”
1-1/8”
10 ton
3’6”
1-1/8”
21
17
12
1-1/2”
5.25”
11.5”
1-1/4”
15 ton
4’0”
1-1/4”
26
21
15
1-3/4”
6”
12”
1-3/8”
15 ton
4’6”
1-3/8”
31
25
18
2”
7”
14”
1-1/2”
20 ton
5’0”
1-1/2”
37
30
21
2”
7”
14”
1-3/4”
22 ton
5’6”
1-3/4”
49
40
28
2-1/4”
8”
16”
2”
30 ton
6’6”
2”
63
52
37
2-1/2”
8”
16”
2-1/2”
37 ton
8’0”
2 -1/4”
77
63
44
2-3/4”
9”
16”
2-1/2”
8’9”

WHEN USING IN BASKET OR CHOKER CONFIGURATION, TAKE LIFTING ANGLES INTO CONSIDERATION. TO OBTAIN FULL RATED CAPACITY, THE PIN THAT THE EYE OF THE SLING PASSES OVER MUST BE A MINIMUM OF 4 TIMES THE DIAMETER OF THE COMPONENT WIRE ROPE.

All slings are proof-tested to 2 times working load limit. Design factor is 5:1